The X5000e in plain numbers, without the brochure language

This is the lightweight X5000e 6x4 electric prime mover as it is actually built: motor TZ40015033 rated 270 kW with 410 kW peak, four speed AMT, drive axle ratio 5.571, gross weight under 49 tonnes, top speed 89 km/h. Wheelbase 3775 plus 1350 mm on an 850 by 270 mm frame, 12R22.5 tyres, 5.5 tonne front axle and 11.5 tonne drum rear axle. Those are the figures that decide where the truck works, so start there rather than at a range headline.

What the specification tells a fleet manager

ParameterValueWhat it means on site
Rated and peak power270 / 410 kWContinuous torque for a shift, extra output for ramps and overtaking
Transmission4 speed AMTNo clutch pedal, consistent pull away loaded
Axle ratio5.571Built for load and grade, not for 100 km/h cruise
Gross weightUnder 49 tStandard 6x4 tractor class, container and flatbed work
Top speed89 km/hSuited to yard, port and national road short haul
CabHigh roof, flat floorStand up room, air suspension seat, automatic AC with PTC heater
SafetyABS plus ESC, lane departure warningRequired by more and more fleet tenders

Range: ask for the number that applies to your loop

Energy use on a loaded 6x4 tractor runs in the region of 110 to 140 kWh per 100 km, and roughly half that empty. Pack capacity depends on the configuration ordered, so the honest way to size the truck is from the route: daily loaded kilometres, empty kilometres, average load, and the depot charge window. We size the pack from those four inputs rather than quoting a single test cycle figure that no fleet will reproduce.

Charging and shift planning

  • Confirm the DC inlet type for the destination market before the build, not after
  • Confirm whether single or dual gun charging is needed for your shift pattern
  • Confirm depot supply capacity in kVA; the charger is often the longer lead item
  • Plan one charger for two to three trucks if each truck has a break and an overnight window

Where this truck earns its place

Factory to warehouse shuttles, port and terminal loops, steel and cement yards, and fixed construction supply runs under 200 km loaded. The 5.571 ratio and the 410 kW peak suit repeated load and stop cycles far better than long flat highway work, and regeneration on every stop returns energy to the pack.

Where it does not fit: line haul beyond the pack, multi yard operations without charging, and depots with no power upgrade plan. For those routes the X5000 550HP Euro V diesel tractor remains the practical answer, and it shares the X5000 cab family so driver training carries over.

Maintenance profile, briefly

No engine oil, no fuel filters, no urea, no exhaust treatment. What remains is tyres, axle and AMT oil, coolant, brakes and the annual high voltage safety inspection. Brake drums still need measuring even though regeneration does most of the retardation, and the low voltage battery is a 165 Ah maintenance free unit that should be tested rather than trusted.

Documents and certification

The unit carries CCC and ECE certification. Export orders also need the battery transport documents under dangerous goods rules, and some markets require their own type approval before registration. Send the destination country with your enquiry and we will tell you which approvals apply before production starts.

Full specification, options and current photos are on the X5000e 6x4 electric tractor page. To size a pack against your own loop, send daily loaded and empty kilometres, average payload, the steepest grade and the depot charge window. Other drivelines are listed on the tractor truck range page.